Wine Guardian Wine Cellar Cooling Systems 50Hz (WG 175) User Manual
Page 34

Settings – Press and hold the “Mode” button for five (5) seconds to access the following
settings.
Deg F or Deg C
Setting 1
Press the “Down” arrow to change temperature
from Deg F to Deg C.
Press the “Up” arrow to change temperature from
Deg C to Deg F.
Low temperature alarm
set point
Setting 2
Press “Mode” button to advance to Setting 2.
Press the “Up” or “Down” arrow buttons to adjust
to the desired set point. Factory default is 10 Deg.
C..
High temperature
alarm set point
Setting 3
Press “Mode” button to advance to Setting 3.
Press the “Up” or “Down” arrow buttons to adjust
to the desired set point. Factory default is 18 Deg
C.
Low humidity alarm set
point
Setting 4
Press “Mode” button to advance to Setting 4.
Press the “Up” or “Down” arrow buttons to adjust
to the desired set point. Factory default is 5%.
High humidity alarm
set point
Setting 5
Press “Mode” button to advance to Setting 5.
Press the up or down arrow buttons to adjust to the
desired set point. Factory default is 95%.
Add or remove
humidifier
Setting 6
Press “Mode” button to advance to Setting 6.
Press the up or down arrow buttons to adjust to the
desired set point. Factory default is zero (0).
Zero (0) = No humidifier
One (1) = Stand-alone remote mounted humidifier
Two (2) = Integral Wine Guardian mounted
humidifier
Fan AUTO or ON
Setting 7
Press “Mode” button to advance to Setting 7.
Press the “Up” or “Down” arrow buttons to adjust
number to the desired set point. Factory default is
zero (0).
Zero (0) = Auto – fan only turns on when there is
a call for cooling or heating
One (1) = Fan On – fan remains on continuously
31