beautypg.com

Wine Guardian Wine Cellar Cooling Systems 50Hz (WG 175) User Manual

Page 34

background image

Settings – Press and hold the “Mode” button for five (5) seconds to access the following

settings.

Deg F or Deg C





Setting 1

Press the “Down” arrow to change temperature

from Deg F to Deg C.

Press the “Up” arrow to change temperature from
Deg C to Deg F.

Low temperature alarm
set point





Setting 2

Press “Mode” button to advance to Setting 2.

Press the “Up” or “Down” arrow buttons to adjust

to the desired set point. Factory default is 10 Deg.
C..

High temperature
alarm set point




Setting 3

Press “Mode” button to advance to Setting 3.

Press the “Up” or “Down” arrow buttons to adjust

to the desired set point. Factory default is 18 Deg
C.



Low humidity alarm set
point




Setting 4

Press “Mode” button to advance to Setting 4.
Press the “Up” or “Down” arrow buttons to adjust

to the desired set point. Factory default is 5%.




High humidity alarm
set point




Setting 5

Press “Mode” button to advance to Setting 5.
Press the up or down arrow buttons to adjust to the

desired set point. Factory default is 95%.




Add or remove
humidifier






Setting 6

Press “Mode” button to advance to Setting 6.

Press the up or down arrow buttons to adjust to the

desired set point. Factory default is zero (0).

Zero (0) = No humidifier
One (1) = Stand-alone remote mounted humidifier
Two (2) = Integral Wine Guardian mounted
humidifier

Fan AUTO or ON



Setting 7

Press “Mode” button to advance to Setting 7.

Press the “Up” or “Down” arrow buttons to adjust

number to the desired set point. Factory default is
zero (0).

Zero (0) = Auto – fan only turns on when there is
a call for cooling or heating
One (1) = Fan On – fan remains on continuously

31