beautypg.com

Vintage Cellars 1800 Series CellarPro User Manual

Page 6

background image

6

 Size & Electrical Specifications

Model

Dimensions
W” x D” x H”

Weight

(lbs)

Operating

Amps

Required

Circuit

1800 QTL/QT/XT/XTS 18 x 16.5 x

10.5

60 3 15-Amp

Dedicated

1800 XTSx

18.1 x 22 x

10.6

70 3 15-Amp

Dedicated

 Ambient Environment

CellarPro cooling units are designed to operate in ambient temperatures between
45°F and 95°F. Except for the 1800XTSx cooling unit, all cooling units are designed

for internal use only, and are not designed for exposure to the exterior.

CellarPro cooling units are not designed to generate heat inside the cellar, so if
temperatures inside the cellar drop below proper wine storage temperatures, the
cooling unit cannot increase the temperature inside the cellar.

Proper temperatures are maintained by transferring heat from inside wine cellars
and exhausting heat through the top (top-vent) or rear (rear-vent) of the cooling units.

 Insulation

CellarPro cooling units are designed to be installed inside wine cellars that have
proper insulation, moisture barriers and an airtight seal from the environment

outside the cellar.

Interior walls and floor
should have a minimum of
R-11 insulation, and a

vapor barrier on the warm
side of the insulation. The
ceiling should have a
minimum of R-19 insulation

and a vapor barrier on the
warm side of the insulation.
Doors also should be
insulated and tightly sealed
with weather stripping

around the perimeter of the
door. Surface-mounted
fixtures are recommended
over recessed lighting,

which can allow air to leak