Vintage Cellars 1800 Series CellarPro User Manual

Page 24

background image

24

Alarms

The cooling unit has both an audible notification and a visual alarm indicator (shown

in “red” on the control panel) that are activated when an alarm is triggered. Please
note: the HA and LA alarms are disabled during the first 23 hours of operation after
the cooling unit is plugged in and/or turned on.
The control panel also will flash a code for each alarm, as follows:

Alarm Code

What it means

What to do

P1, P3

Probe Failure

Call CellarPro at 877.726.8496

HA

The temperature inside
the cellar is too warm
(above 70°F for more

than 1 hour)

Check seals;
Check if door was left open;
Lower the ambient temperatures

HA2 The

condenser

temperature is too high
(above 140°F for 2

hours)

Check for appropriate installation,
ventilation, ambient conditions and
cooling capacity (Chapter II)
Clean the condenser coils (see
“Maintenance” in Chapter IV);
Check for obstructions to the intake
and/or exhaust vents;
Check that the condenser fan is
operating

LA

The temperature inside
the cellar is too cold
(below 45°F)

Raise the ambient temperature;
Raise the “Minimum Set Point”

LA2

The temperature at the

condenser coils
(outside the cabinet)
has dropped below the
alarm temperature

setting

Call CellarPro at 877.726.8496