- Slide the light fixture off the second mounting bracket.
10. With 7/16 socket wrench, remove the two hex head bolts that attach the
cooling unit to the ceiling of the cellar. Save these bolts! Leave mounting
brackets attached to the cooling unit so that the proper location can be
duplicated with the replacement cooling unit.
PLEASE NOTE: If the nut in the ceiling becomes loose, you will need to use
pliers from the top of the cabinet to hold the nut and keep it from spinning
with the bolt.
11. The cooling unit is now free to remove. Drop front end down, and move side to
side to free from cabinet opening.
CAUTION: Two people may be required to remove the cooling unit, which weighs
58 pounds. Do not let the cooling unit drop on unprotected bottle racks.
TO INSTALL THE REPLACEMENT COOLING UNIT
1. Carefully remove the replacement cooling unit from the packaging. NEVER store
the cooling unit upside down or on its side, and NEVER turn the unit upside down.
You may reuse this packaging for shipping or storing the old cooling unit
2. Remove any materials that have been packed inside the exhaust cavity.
3. Before installing the cooling unit, make sure it works by plugging it in and
letting it run on a hard, flat surface for no more than 5 minutes. Check that
cold air is being produced by the unit.
PLEASE NOTE:
CellarPro cooling
systems are programmed with a 3-minute delay at start-up to protect its
internal components.
4. For top-vent configurations, make sure that the exhaust panel is installed at
the REAR of the cooling unit, so that the top of the unit has an opening for the
hot air exhaust. For rear-vent configurations, make sure that the exhaust
panel is installed in the TOP of the cooling unit, so that the rear of the unit has
an opening for the hot air exhaust. In both configurations, return air from
outside the cellar will come into the coils at the rear of the cooling unit.
5. If using mounting clips, attach the clips to the FRONT of the cooling unit so that
the short side slides under the metal fold near the top of the cooling unit, and
space the clips so that they’ll line up with the holes in the ceiling of the cellar. You
may need to remove the front grill (attached with two screws on each side of the
cooling unit) in order to slide the mounting clips under the sheet metal, then
replace the front grill after the clips are in place.