beautypg.com

Fan speed reference – Vintage Cellars WhisperKOOL InCellar User Manual

Page 6

background image

InC

033114

Page 4 | 1-800-343-9463

Your fan speed selection will depend on the amount of heat that needs to be removed from the cellar. Fan speed

selection will depend on the cellar size, insulation factor, door seal and desired wine temperature. When initially

installing the unit, set the fan speed to High setting for a quick chill down. Once the temperature of the cellar reaches

the desired temperature, you may be able to select a lower fan speed to handle the normal load. In the event the

temperature outside goes above 90 degrees, (when exhausting to the outside) you may need to select the higher fan

speed.

Model

8000

8000

Speed Selection

Low

High

Air Flow

(CFM)

275

Evaporator Side

257

Condenser Side

303

Evaporator Side

279

Condenser Side

Sound

(dBA)

65

Evaporator Side

54

Condenser Side

68

Evaporator Side

56

Condenser Side

Cooling Capacity

(BTU/h)

5610

6206

FAN SPEED REFERENCE

* To get a feeling for decibels, a food blender at 3ft is 90 dBA, garbage disposal at 3ft is 85 dBA, vacuum cleaner at

10ft is 75 dBA, normal speech at 3ft is 79 dBA, dishwasher in the next room is 55dBA, Quiet night is 35dBA