TROUBLESHOOTING GUIDE

Unit leaks water

Possible Cause

Solution

Unit is not level

Unit should be level to prevent leaking.

Drain line clogged or kinked

Check drain line to make sure water can flow freely.

Drain is clogged preventing water form escaping

Disconnect drain and clear out, open access door and check

drain for blockage

Coil is iced causing drain pan ice and water overflowing

Melt ice with blow drier. Soak up with a towel

Unit runs but does not cool

Possible Cause

Solution

Lack of air flow

Make sure fan is unobstructed; clean evaporator if necessary.

Compressor not running

Contact Customer Service at 800-343-9463

Unit undersized

Contact Customer Service at 800-343-9463

Compressor is overheating

Shut system off for 1 hour to allow compressor to cool. Turn

back on and check for cooler air flow out. If compressor runs,

check and clean condenser coil as possible cause of compressor

overheating. If problem repeats, contact you installing technician

to assist with troubleshooting.

Evaporator fan runs but compressor does not

Possible Cause

Solution

Running an Anti-Frost Cycle
Compressor and/or starting components faulty

Please contact the installing technician to troubleshoot.

System may be performing the WHM function

Allow cooling system to revert back to cooling mode.

Compressor may have overheated.

Shut system off for 1 hour to allow compressor to cool. Turn

back on and check for cooler air flow out. If compressor runs,

check and clean condenser coil as possible cause of compressor

overheating. If problem repeats, contact you installing technician

to assist with troubleshooting.

Compressor runs but evaporator fan does not

Possible Cause

Solution

Faulty fan motor

Please contact the installing technician to troubleshoot.

Faulty Controller

Please contact the installing technician to troubleshoot.

Compressor short cycles

Possible Cause

Solution

Unit blows on bottle probe

Move bottle probe to a more central location.

Unit low on refrigerant charge

Please contact the installing technician to troubleshoot.

Condensing fan motor/capacitor faulty

Please contact the installing technician to troubleshoot.

Compressor and /or starting components faulty

Please contact the installing technician to troubleshoot.

Humidity in cellar too low

Possible Cause

Solution

Not enough moisture

Raise the Fdc setting to increase the humidity level