INCELLAR UNIT SPECIFICATIONS

Model

InCellar 8000

Low Speed

InCellar 8000

High Speed

Cellar Size (cu. ft.)

2000

2000

Dimensions

15 1/4”w x 36.25”h x 16”d

BTUh with 90° air entering

the Condenser Coil

5610

6206

CFM

275

Evaporator Side

257

Condenser Side

303

Evaporator Side

279

Condenser Side

Refrigerant

R-134a

Compressor HP

1/2+

1/2+

Voltage Rating

(20 amp

dedicated circuit required)

120V

Weight (lbs)

131

131

AMPS

(Starting/Running)

38.6

Starting

9.2

Running

40

Starting

9.5 Running

dBA

65

Evaporator Side

54

Condenser Side

68

Evaporator Side

56

Condenser Side

Drainline

1/4” I.D

Installation

Partially Ducted System. Maximum Ducted feet: 15’

Thermostat

Digital Control Display

Temp. Delta

55°F

Temperature differential between the cellar temperature and condenser air intake temperature.

Warranty

2 year parts and labor

Compressor On

Unit is in Anti-Frost Mode

Fans are On

Alarm is Present

Temperature Measurement

QUICK REFERENCE GUIDE

Controller Layout

Refer to page 24 for complete listing of buttons and symbols.

Menu Navigation

& Value Increase

*Press and hold

to manually enter

anti-frost mode.

Power On/Off

(hold for approx. 3 seconds)

& Escape

Menu Navigation

& Value Decrease

Probe Values &

Alarm Folder

*Press and hold to

enter the parameter

menu.