TROUBLESHOOTING GUIDE

Pump runs all the time

Possible Cause

Solution

Float is positioned with the magnet facing downwards.

Reposition the float with the magnet facing up wards.

The float is not in the correct location.

Check that the float is located inside the reservoir around

the sensor column.

The top is not secured properly to the reservoir.

Make sure that the top is clipped firmly on to the reservoir.

Sludge has built up and is preventing the float to rest on

the bottom of the reservoir.

Clean with anti bacterial solution. Note: The pump will

only switch off when the float is actually resting on the

bottom of the reservoir.

The evaporator produces more condensate than the

pump can handle.

The pump is too small and must be replaced with a

different type.

Pumps runs but does not pump any water

Possible Cause

Solution

Evaporator has been disconnected from reservoir.

Connect the evaporator’s drain outlet hose onto the drain

inlet on the reservoir.

Reservoir has been disconnected pump.

Connect the reservoir outlet to the pump inlet.

Restriction in one of the hoses.

Remove all kinks and debris from the drain hose

Reservoir, filter and discharge hose are being restricted by

sludge and debris.

Clean with anti bacterial solution.

Pump does not operate

Possible Cause

Solution

Power is not reaching the Pump

Contact Customer Service at 800-343-9463

Pump is not wired correctly

Contact Customer Service at 800-343-9463

The pump was too hot and the thermal cut out has been

activated.

The pump will automatically reset once the pump has

cooled down.