beautypg.com

Vintage Cellars CellarPro Owners Manual User Manual

Page 4

background image

3

I m p o r t a n t N o t e s

• Before plugging in and operating your CellarPro cooling unit, remove any

materials that have been packed inside the exhaust cavity.

• Wait 24 hours before plugging in and operating your CellarPro cooling unit.

• Before installing the cooling unit, make sure it works by plugging it in and letting it

run on a hard, flat surface. Check that cold air is being produced by the unit.

• NEVER turn the cooling unit on its side or upside down

• The cooling unit should be plugged into an outlet connected to a 15-amp circuit

• Before installing the cooling unit, make sure that the exhaust panel is installed in

the correct position – it MUST cover
either the TOP or the REAR exhaust
vent:

o

TOP VENT CONFIGURATION::
If the hot air will be discharged
through the TOP of the cellar,

install the exhaust panel on the
BACK of the cooling unit (as
shown in the Picture A). In this
configuration, the cavity on TOP

of the cooling unit is OPEN. Picture

A

Top

Vent

Configuration

o

REAR VENT CONFIGURATION:

If the hot air will be discharged
through the REAR of the cellar,
use the exhaust panel to seal

the TOP of the cooling unit (as
shown in the Picture B). In this
configuration, the cavity at the
REAR of the CellarPro is OPEN.

Picture

B

Rear Vent Configuration