Advanced Settings
CellarPro cooling systems can be programmed with advanced settings to achieve
more control over conditions inside the cellar.
To access the advanced settings, press the “Set” and “Down” buttons together for
three seconds. Then, use the “Up” and “Down” buttons to cycle through the settings
(see below). To change a setting, press the “Set” button again, use the “Up” and
“Down” buttons to change the setting, and press “Set” again to lock in the change.
The display will blink three times to confirm the change.
This setting determines the Temperature Differential when
the cooling unit cycles on. The factory preset for this setting
is “4”.
The recommended range for this setting is 4-5, which will
allow the cooling unit to cycle “on” and “off”, will maintain
consistent air temperatures throughout the cellar, and
results in liquid temperature swings of approximately 0.5°F
This setting increases or decreases the humidity inside the
cellar. The factory preset for this setting is “0”.
The recommended range for this setting is 0-6. If the
humidity inside the cellar is too low at a setting of “0”, this
setting should be increased in increments of 1-2 units until
the desired humidity inside the cellar is achieved.
This setting designates the High temperature inside the
cellar at which the alarm is triggered. The factory preset for
this setting is “70”.
We recommend leaving this setting at the factory preset.
This setting designates the Low temperature inside the
cellar at which the alarm is triggered. The factory preset for
this setting is “45”.
We recommend leaving this setting at the factory preset.
This setting increases or decreases the Temperature
Differential for the Energy Savings Mode. The factory preset
for this setting is “4”.
The recommended range for this setting is 2-4.