beautypg.com

Vintage Cellars CellarPro Owners Manual User Manual

Page 17

background image

16

Basic Operation

Power On/Off Button Press “Power On/Off” to turn the unit on and off

When the “Compressor On” indicator light is on (Row 1), the

Compressor is running
When the “Fan On” indicator light is on (Row 1), the Fan is
running

Digital Display

The temperature displayed on the control indicates the real-
time air temperature as measured by Probe 1 (P1) located
behind the front grill of the cooling unit

Set Button

The cooling unit is factory preset with a Minimum Set Point of
58°F and a Temperature Differential of 4°F. This means that

the cooling unit will turn on when the air temperature as
measured by Probe 1 (P1) rises above 62°F (58°F + 4°F), and

turn off when the air temperature measured by P1 falls below
58°F. This range in AIR temperature will result in 1/2°F

variation in LIQUID temperature.
To view the Minimum Set Point, press the “Set” button for one

second
To change the Minimum Set Point,

1. Press the “Set” button for three seconds until “°F”
blinks
2. Press the “Up” or “Down” button
3. Press the “Set” button to confirm
The “Set” temperature will blink three times to indicate
confirmation

The recommended range for the Minimum Set Point is 55 -
60°F.

To change the Temperature Differential, see the Advanced
Instructions below.