Protection Mechanisms
Protection
Mechanisms
To protect the components in the cooling unit as well as the
wine inside the cellar, the cooling unit is programmed to
shut down certain components under certain
circumstances, as follows:
Scenario
What it means What
happens
P1 Alarm
Probe 1, which senses
the temperature inside
the cellar and controls
the on/off cycles of the
cooling unit, has failed
The cooling unit enters a timed
auto-cycle mode until Probe 1 is
repaired or replaced. In this mode,
the cooling unit will turn for 12
minutes and off for 8 minutes.
P2 > 70°F for more
than 1 hour
The evaporator probe
is measuring
temperatures that are
too warm
The evaporator fan will turn off
until the evaporator temperature
falls below 70°F
Optional Protection
Mechanisms
CellarPro cooling systems can be programmed to turn off
the compressor and condenser fan in the event of an HA2
alarm, as described below. If you’d like to turn on this
protection mechanism, please call us toll-free at
877.726.8496
P3 > 125°F for more
than 2 hours
The condenser probe
is measuring
temperatures that are
too hot
The compressor and condenser
fan will turn off until the condenser
temperature falls below 120°F