Protection Mechanisms

Protection
Mechanisms

To protect the components in the cooling unit as well as the
wine inside the cellar, the cooling unit is programmed to
shut down certain components under certain

circumstances, as follows:

Scenario

What it means What

happens

P1 Alarm

Probe 1, which senses

the temperature inside
the cellar and controls
the on/off cycles of the
cooling unit, has failed

The cooling unit enters a timed

auto-cycle mode until Probe 1 is
repaired or replaced. In this mode,
the cooling unit will turn for 12
minutes and off for 8 minutes.

P2 > 70°F for more

than 1 hour

The evaporator probe
is measuring
temperatures that are
too warm

The evaporator fan will turn off
until the evaporator temperature
falls below 70°F

Optional Protection
Mechanisms

CellarPro cooling systems can be programmed to turn off
the compressor and condenser fan in the event of an HA2

alarm, as described below. If you’d like to turn on this
protection mechanism, please call us toll-free at
877.726.8496

P3 > 125°F for more
than 2 hours

The condenser probe
is measuring
temperatures that are
too hot

The compressor and condenser
fan will turn off until the condenser
temperature falls below 120°F