Reset battery ram – Ring Communications CB901EX User Manual
Page 77

April 2012 Operations Manual CB901EX
RESET BATTERY RAM
The Battery RAM must be initialized when the system is first installed. All programmable features
are set to default and all station are assigned call numbers .
1.
Set all 8 dip switches in SW2 (PCB1019) to OFF.
2.
Set SW3 (PCB1019) for number of call digits.
3.
Push and release the Reset Switch on PCB1019 (SW4).
LED M (PCB1019) will blink 2 times during RAM Test (apx. 2 sec.).
The RAM will initialize (1 sec.).
LED M will flash rapidly to indicate that the initialization is complete.
4.
Set SW2 (PCB1019) to proper network address
5.
Push and release the Reset Switch on PCB1019 (SW1).
LED M (PCB1019) will blink 2 times during RAM Test .
The system is now operational.