Error messages – Rice Lake Lift Truck/Pallet Jack Scales - Intercomp PW800 User Manual
Page 17

PW800, Users
Rev O, January, 2008
17
Error Messages
[Minus signs cycle across the display]: The PW800 has entered sleep mode. Press any key
or change the weight to return to normal weighing. NOTE: a pressed key here will perform its
designated function as well as exit the scale from sleep mode.
[Minus signs fill display]: The PW800 is waiting for a stable reading to continue.
DISE
DISE
DISE
DISE
Display error, the scale is unable to display the number completely. If no weight
on the scale, press zero to return the weight reading to zero.
LB
LB
LB
LB
Low batteries. This message blinks, and if ignored too long the unit will shut itself
off.
OE
OE
OE
OE
The scale is over capacity or outside the A/D converter range. Reduce the load to
the scale. If the PW800 continues to display “OE
OE
OE
OE”, the problem could be a bad load
cell, bad load cell wiring, or a bad chip on the AD 20-bit board (U3, U4, U5, U6,
VR2, VR4, or U11)
EEPE
EEPE
EEPE
EEPE
EEPROM error, the scale has had it's calibration corrupted or destroyed; the scale
will require calibration.
OL
OL
OL
OL
Zero overload; the PW800 has attempted to zero a reading outside of its zero-
range limit. This message can occur only when the 'Zero range' or 'Canadian
specifications' is turned on. See EE-08
EE-08
EE-08
EE-08, EE-09
EE-09
EE-09
EE-09 in the 'calibration' section.
E-0
E-0
E-0
E-0
This message occurs if the scale is turned on with a load applied which is greater
than
±
10% of capacity. Return the scale's load to zero. This only occurs when
'Canadian specifications' or 'Initial zero range' is turned on. See EE-09
EE-09
EE-09
EE-09 and EE-10
EE-10
EE-10
EE-10
in the 'calibration' section.
E-2
E-2
E-2
E-2
This error will be display if there is a saved total and the user tries to switch units or
press the NET/GROSS key. Clear the total by pressing TOTAL and CLEAR.