Rice Lake Lift Truck/Pallet Jack Scales - Intercomp PW800 User Manual
Page 15

PW800, Users
Rev O, January, 2008
15
2: The IZSM (initial zero setting mechanism on power up) must be within +/- 10%
of the zero obtained at calibration.
3: The push-button zero and AZSM can only operate within +/- 2% of the IZSM.
4: The over-capacity point is 103% of capacity above the IZSM.
18. The scale shows “EE-10
EE-10
EE-10
EE-10”. Press the NET/GROSS and MODE keys. The scale
shows the current 'Initial zero range' setting. Use the following table to select the
'Initial zero range' setting:
Setting
Initial zero range
0
Off
1
On
A '0' setting implies: The initial zero setting mechanism (IZSM) will work over the
entire range of the scale capacity and the over-capacity point is 103% above the
zero obtained at calibration.
A '1' setting implies: The IZSM must be within +/- 10% of the zero obtained at
calibration and the over-capacity point is 103% above the IZSM.
19. The scale shows “EE-11
EE-11
EE-11
EE-11”. Press the NET/GROSS and MODE keys. The scale
shows the current graduation selection. Use the following table to select a
graduation value.
Settings
Count by in lb
Count by in kg
0
100
50
1
50
20
2
20
10
3
10
5
4
5
2
5
2
1
6
1
0.5
7
0.5
0.2
8
0.2
0.1
9
0.1
0.05
10
0.05
0.02
11
0.02
0.01
20. The display shows “EE-12
EE-12
EE-12
EE-12”. This parameter is reserved for future use. Press
NET/GROSS and MODE keys together twice to continue.
21. The scale shows “EE-13
EE-13
EE-13
EE-13”. Press the NET/GROSS and MODE keys. The display
shows the current circuit board ID#. This is used in multi scale applications. The
circuit board ID is used for identification.