8. The scale shows “EE-00
EE-00
EE-00
EE-00”. Press the NET/GROSS and MODE keys. Enter the
sample rate (1 to 127). The sample rate is the number of past readings that are
averaged together to make a reading.
9. The scale shows “EE-01
EE-01
EE-01
EE-01”. Press the NET/GROSS and MODE keys. Enter the sleep
mode time (the number represents minutes). The sleep mode time is how long the
scale's display will remain ON without any activity (a key being pressed or a change
in weight). An entry of 0 turns the sleep mode feature OFF. The sleep mode is
designed to conserve battery life on scales with a LED display.
10. The scale shows “EE-02
EE-02
EE-02
EE-02”. Press the NET/GROSS and MODE keys. Enter the auto
off time (the number represents minutes). The auto off time is how long the scale will
remain ON without any activity (a key being pressed or a change in weight). An entry
of 0 turns the auto off feature OFF (The scale would remain on until turned off).
11. The scale shows “EE-03
EE-03
EE-03
EE-03”. Press the NET/GROSS and MODE keys. Enter the baud
rate of the serial output (0 to 7).
Setting
Baud Rate
0
9600
1
4800
2
2400
3
1200
4
600
5
300
6
150
7
75
8
19.2K
9
38.4K
12. The scale shows “EE-04
EE-04
EE-04
EE-04”. Press the NET/GROSS and MODE keys. Enter what unit
of measure the scale should turn ON in; pounds or kilograms (0 to 1).
Setting
Units to turn ON in
0
pounds (lb)
1
kilograms (kg)
13. The scale shows “EE-05
EE-05
EE-05
EE-05”. Press the NET/GROSS and MODE keys. Enter the
desired APW decimal position. See the section on APW for details.
Setting
APW decimal position
0
no decimal
1
1 decimal place
2
2 decimal places