Journal print format & printout sample – Rice Lake DWM-IV Weighmeter Series 9 Setup Manual User Manual
Page 27

25
Journal Print Format & Printout Sample
Journal Print Format is enable d by the settings: 1) Custom Print Format Type (C3.6
“PFM” = CPR) with the proper Journal Print Format in C10.1 as will be described
below, 2) Date/Time Setup Enable (C1.4 “DTM” = E) and 3) Journal Print Feature
Enable (C1.5 “JPR” = E) .
Following commands are specially provided for Journal Pri nter Print Formats:
Ø Journal Print Format Commands (FX)
Where X = Format No. 1 to 5.
Each of the foll owing command defines the fo rmat header or a start position of
print format.
F1 = Start of Main Title Format
F2 = Start of Sub Title Format
F3 = Start of Batch Weighing Format
F4 = Start of Sub Total Format
F5 = Start of Grand Total Format
Note: At the end o f each format, “CR/LF” pair will be printed, except at the end of F5.
Ø Code and Number Format Commands (NX)
Where X = Format No. 1 to 4.
Each of the f ollowing command represents the Code or Numeric Data to be printed.
N1 = Product Code (10 Alpha -Numeric Characters)
N2 = Consecutive No. (5 Numeric Characters)
N3 = Sub Total Counts (5 Numeric Characters)
N4 = Grand Total Counts (5 Numeric Characters)
Ø Weight and Unit Format Commands (WX.Y.U)
X = Weight Type (0 = Net, 1 = Gross, 2 = Tare,
3 = Sub Tot al Weight, 4 = Grand Total Weight).
Y = Field Wid th (Includes “.” if any)
U = Appends the current unit of measurement to the weight and opti onal tare entry
flag.
(1) U = 0: Not print current unit of measurement. (Same as W.X.Y)
(2) U = 1: Appends the current unit of measurement (“^kg”) to the printed weight.
(3) U = 2: Appends as d escribed in (2) but with 3 additional characters of tare
entry flag:
(a) “^^^” For Pushbutton Tare, Gross or Net We ight (^ = Space).
(b) “(K)” For Keyboard Tare or Recall Tare Weight.
q Example: Following will print the net weight right justified with a field width of
8 and will finally print a diffe rent type of optional current unit of measurement
description:
W0.8.0 = without current unit: e .g. “ 3456.78” (same as W0.8).
W0.8.1 = 1 space and 2 characters of current unit: e.g. “ 3456.78 kg”.
W0.8.2 = 1 space an d 2 characters of current unit with 3 extra spaces of tare
flag. e.g. “ 3456.78 kg ” (same as W.0.8U).
Ø Time Format Commands (TX)
Where X = Time Format No. 1 to 8 as fo llows:
Command
Format
Print Out
T1
H:MM
2:13
T2
HH:MM
02:13
T3
H:MM AM/PM
2:13 AM
T4
HH:MM: AM/PM
02:13 AM
T5
H:MM:SS
2:13:00
T6
HH:MM:SS
02:13:00
T7
H:MM:SS AM/PM
2:13:00 AM
T8
HH:MM:SS AM/PM
02:13:00 AM