2 external ethernet cabling, 3 reassembling the enclosure, 4 ethernet option parts kit contents – Rice Lake CW-90X Over/Under/Washdown Checkweigher - Ethernet User Manual
Page 9

Ethernet TCP/IP Card Installation Manual - Installation
5
Figure 2-3. Ethernet Card Serial Wiring
4. Use cable ties to secure loose cables inside the
enclosure away from high voltage circuits
2.1.2
External Ethernet Cabling
Configure external Ethernet cabling using either the
RJ-45 connector (LX1) or the hardwire connection to
J4 on the Ethernet card. When using an external RJ-45
connector, we recommend using a DNET 1 network
surge suppressor (PN 72682) wired through a cord
grip with the RJ-45 socket left outside of the
enclosure.
2.1.3
Reassembling The Enclosure
1. Once cabling is complete, position the
backplate over the enclosure and reinstall the
backplate screws. Use the torque pattern
provided in the indicator’s installation manual
to prevent distorting the backplate gasket.
2. Ensure no excess cable is left inside the
enclosure and tighten the cord grips.
3. Reconnect power to the indicator.
Contact factory for washdown option.
2.1.4
Ethernet Option Parts Kit Contents
Table 5-4 shows the parts kit contents for PN 71986.
shows the parts kit contents for PN 77205.
Pin
Signal
1
Gnd
2
TxD+
3
TxD-
4
RxD+
5
RxD-
6
Gnd
Table 2-5. Ethernet Card J4 Pin Assignment
Ether net
Car d
Indicator
Port
TXD
RXD
GND
TXD
RXD
GND
PN
Description
14822
Screws, 4-40NCx1/4 (2)
15631
Cable tie, 3 in nylon (2)
54325
Unshielded cable, grey 60 in (1)
78269
RJ-45 cable, 5 in (1)
83267
Ethernet card, RS-232/Ethernet (1)
72763
Ethernet CD (1)
Table 2-6.
PN 71986
Parts Kit Contents
PN
Description
14822
Screws, 4-40NCx1/4 (2)
15631
Cable tie, 3 in nylon (2)
54325
Unshielded cable, grey 60 in (1)
78269
RJ-45 cable, 5 in (1)
72696
Cable, 3-pin to blunt 3-wire (1)
83267
Ethernet card, RS-232/Ethernet (1)
72763
Ethernet CD (1)
Table 2-7.
PN 77205
Parts Kit Contents
Note