Installation Manual
1.5
Summary of Changes
Changes to recent editions of this manual are listed
below:
Version 3.07
•
Support has been added for the dual-channel
analog output card (PN 103138) and the
ControlNet interface card (PN 103136).
•
New OVRBASE parameter, on the
REGULAT submenu of the FEATURE menu,
allows specification of calibrated or scale zero
as the base for overload calculation. See
page 43 for more information.
•
A new top-level menu, FLDBUS, is now
shown if a DeviceNet, Profibus, EtherNet/IP,
or ControlNet is installed.The two parameters
u n d e r t h e F L D B U S m e n u a l l o w b y t e
swapping to be enabled (SWAP parameter)
and for the transfer size of the swapped bytes
t o b e s p e c i f i e d ( D ATA S I Z E ) . S e e
S e c t i o n 3 . 2 . 8 o n p a g e 4 9 f o r m o r e
information.
•
The default A/D sample rate (SMPRAT
parameter on the SCALES menu) has been
changed from 120 to 30 Hz.
•
The KEXIT command has been removed and
r e p l a c e d w i t h K S AV E E X I T. ( S e e
Section Table 9-1. on page 84.)
•
Error codes returned on the XE serial
command have been updated (see Table 10-3
on page 103).
Version 3.05-3.06
•
Support for local/remote indicator configurations
provides function equivalent to a legal-for-trade
remote display with keypad for truck scale and
similar applications. See Section 10.5 on
page 106 for more information.
•
The description for setting rate of change (ROC)
parameters has been changed. See Table 3-3 on
page 27 for details.
•
New values have been added to the STREAM
parameter on the SERIAL menu to allow
streaming of keypad events to another indicator
(4KEYS, KEYPAD) and, for the local/remote
function, to send the complete display image
(DISPLAY). See Section 3.2.2 for more
information.
•
Reprinting of any previous print transaction is
now supported by the alibi feature. The feature is
enabled using the ALIBI parameter on the
FEATURE menu; print transactions can be
recalled by assigning an
Alibi
softkey, also
configured using the FEATURE menu (see
Section 3.2.3 on page 38).
•
New IMAGE parameter on the FEATURE menu
a l l o w s i n v e r s i o n o f t h e d i s p l a y i m a g e
(blue-on-white or white-on-blue) for support of
the outdoor display option. See Section 3.2.3.
•
Display and printing of audit trail information is
described in Section 10.11 on page 116.
Version 3.00
•
The desktop model of the
920i
has been
discontinued. Drawings and parts lists for the
desktop model have been removed from this
manual.
•
Added support for multi-range and
multi-interval scale configurations.
•
Zero tracking, zero range, and motion band
parameters (SCALES menu) have been
changed to allow numeric values.
•
Added peak hold function to SCALES menu.
•
Added last zero and temporary zero functions
to calibration menus to allow recalibration
based on previous zero values.
•
Enhanced print formatting with addition of
audit format and twenty auxiliary formats.
•
The SERIAL menu has been restructured to
provide additional parameters for configuring
RS-485 communications. See Figure 3-10 on
page 35.
•
A new digital input count (DINCNT) setpoint,
used to count digital input pulses, has been
added to the supported setpoint kinds. See
Section 8.0 on page 65.
•
A SENSE parameter has been added to
optionally invert the value of setpoint digital
outputs. See Section 8.0 on page 65.
•
TRIGGER (digital output trigger) has been
added as a selection under the DIG I/O menu
(see Section 3.2.6 on page 46) for custom
applications.
•
Support has been added for EtherNet/IP and
analog input/thermocouple option cards.