2 id#1 and id#2 softkeys, 3 delay after fill, 4 delay after discharge – Rice Lake 920i Bulkweigher 107 - 108 - 109 User Manual
Page 18: 5 discharge delay, 6 slow cycle time, 7 draft subtotals

14
920i Flexweigh Systems Bulkweigher
3.2
ID#1 and ID#2 Softkeys
The ID keys allow an operator to log an extra data field. The ID softkeys can be either enabled or disabled and
appear on the main screen (see Figure 5-7) to allow the operator to enter more data, such as name. Press the
ID#1
or
ID#2
softkey and the following screen is displayed.
04/17/2012
02:17PM
SCALE #1
No
Enable ID#1
3
SCALE #1
Gross
Lb
Yes
ID #1: (Disabled)
ID #2: (Disabled)
Slow Cycle Time (sec): 45.00
Delay After Fill (sec): 3.0
Delay After Discharge (sec): 3.0
Discharge Delay (sec): 3.0
Subtotal Print: 3
Program: Express xxxx, PN
Setup Menu
Figure 3-1. ID Softkey Screen Display
Press
Yes
to Enable ID#1 or ID#2. If Yes is selected the operator is prompted to
Enter ID#1 Name
. Use the numeric
keypad on the indicator and press
enter
to save that ID name. Press
No
to disable ID#1 or ID#2.
3.3
Delay After Fill
The
Delay After Fill
softkey specifies the delay after fill in seconds to allow the scale to settle and the gate to
mechanically close. At the end of this time delay, the gate closed switch is checked. If not closed, the system enters
an error condition. No further operation is allowed until the condition is cleared. The default is 3.0 seconds. To
change the default, enter the new time and press
enter
to save the value.
3.4
Delay After Discharge
The
Delay After Discharge
softkey specifies the delay after discharge in seconds to allow the scale to settle and the
gate to mechanically close. At the end of this time delay, the gate closed switch is checked. If it is not closed, the
system enters an error condition. No further operation will be allowed until the condition is cleared. The default is
3.0 seconds. To change the default, enter the new time and press
enter
to save the value.
3.5
Discharge Delay
The
Discharge Delay
softkey specifies the length of time in seconds before the gate opens and the scale starts dis-
charging.
The default time is 3.0 seconds. To change the default, enter the new time and press
enter
to save the value.
3.6
Slow Cycle Time
Specifies the period of time allowed to complete a fill or discharge cycle. The purpose of the slow cycle timer is to
detect starved or blocked product flow. If a fill or discharge cycle is started that does not complete within the
selected slow cycle time period, a slow cycle alarm is displayed and a slow cycle alarm output is turned on.
The system remains in a slow cycle alarm state until the fill or discharge cycle does complete, until the end cycle
switch input, until the reset switch input, or until a manual mode switch input.
3.7
Draft Subtotals
Specifies the number of drafts between the subtotal printout.