1 setup menu, 1 entering the setup menu, 2 entering a password – Rice Lake 920i Bulkweigher 107 - 108 - 109 User Manual
Page 15: Entering the setup menu, Entering a password

Setup Menu
11
3.1
Setup Menu
The 920i Flexweigh Systems Bulkweigher has various setup parameters. They are explained in detail in the follow-
ing sections.
3.1.1 Entering the Setup Menu
Note
The front panel E-Stop button must be in the stopped position (pushed in) to enable any of the following key-
pad entries.
Press the
Setup Menu
softkey (shown in Figure 5-1) on the main menu screen, and the system displays time and
date, setup password and ID softkeys.
04/17/2012
02:25PM
SCALE #1
Setup Menu
SCALE #1
Presets
0
Gross
Lb
Accum: (0) 0
Draft
Empty
Preact
Target
1000 lb
5 lb
OFF (0) lb
5000 lb
Discharge Gate Closed
Fill Gate Closed
Manual
Receiving
Figure 3-1. Main Startup Menu Screen
3.1.2 Entering a Password
Certain screens can be password protected depending on the user. To access password parameters,
press the
Setup Password
softkey.
Setup
Password
If a system password has previously been entered, proceed to step 3.
If no system password has been previously entered, proceed to step 2.
1. Press the
Setup Password
softkey.
2. The system prompts with
Enter New Password
.
04/17/2012
02:15PM
SCALE #1
Cancel
End
Enter New Password:
3
SCALE #1
Gross
Lb
Home
ID #1: (Disabled)
ID #2: (Disabled)
Slow Cycle Time (sec): 45.00
Delay After Fill (sec): 3.0
Delay After Discharge (sec): 3.0
Discharge Delay (sec): 3.0
Subtotal Print: 3
=>
Program: Express xxxx, PN
Setup Menu
Figure 3-2. Setup Menu Enter Password
3. Enter the desired password and press
enter
on the 920i.
4. The system checks the entered value against the system password and performs one of the following actions:
•
Valid entry — displays the setup menu screen and softkeys.
•
Invalid entry — momentarily prompts
Invalid password
and exits this sequence of operation.