Commands 21

Read Setpoint Hysteresis as Float

Command: 321, 0x141
Parameter: Setpoint number

Command 321 returns the hysteresis value for the specified setpoint in floating-point
format. This command is only valid if the setpoint is configured and requires a
hysteresis value. Batch status is returned in place of the indicator status.

Read Setpoint Bandwidth as Float

Command: 322, 0x142
Parameter: Setpoint number

Command 322 returns the bandwidth value for the specified setpoint in floating-point
format. This command is only valid if the setpoint is configured and requires a
bandwidth value. Batch status is returned in place of the indicator status.

Read Setpoint Preact as Float

Command: 323, 0x143
Parameter: Setpoint number

Command 323 returns the preact value for the specified setpoint in floating-point
format. This command is only valid if the setpoint is configured and requires a preact
value. Batch status is returned in place of the indicator status.