Rice Lake 880 Performance Series Panel Mount Indicator/Controller - ProfiNet Interface Option Installation and Programming Manual User Manual
Page 23

Commands 19
Enable Bus Command Handler
Command: 128, 0x80
Parameter: None
Command 128 enables the bus command handler in a user program. While this
handler is enabled, all other PLC commands are disabled.
No Operation
Command: 253, 0x0FD
Parameter: Scale number
Command 253 provides a command to use between operations, as necessary, without
causing the indicator to perform any action. Indicator status and weight for the
specified scale is returned.
Reset Indicator
Command: 254, 0x0FE
Parameter: None
Command 254 provides a command to remotely reset the indicator. No data is
returned.
Return Status and Current Weight as Float
Command: 256, 0x100
Parameter: Scale number
Command 256 returns the status and weight of the specified scale in floating-point
format, without changing the display. This command also causes the format-
independent commands to return a value in the floating-point format. Returns current
weight at a floating-point format.
Enter Tare as Float
Command: 268, 0x10C
Parameter: Scale number
Value: Tare weight
Command 268 enters a tare for the scale selected in floating-point format. The
indicator returns the tare weight as taken, or 0 for no tare.
Read Gross Weight as Float
Command: 288, 0x120
Parameter: Scale number
Command 288 returns the gross weight value for the specified scale in floating-point
format.
Read Net Weight as Float
Command: 289, 0x121
Parameter: Scale number
Command 289 returns the net weight value for the specified scale in floating-point
format.
Read Tare as Float
Command: 290, 0x122
Parameter: Scale number
Command 290 returns the tare weight value for the specified scale in floating-point
format.