Error Messages

Error NO.

Error Messages

Error Description

02XX

"Input over voltage"

The input voltage is too high

03XX

"Input under voltage"

The input voltage is too low

04XX

"Output over voltage"

The output voltage is too high

05XX

"Low battery voltage"

The voltage of the connected battery

is too low

06XX

"High battery voltage"

The voltage of the connected battery

is too high

07XX

"Output over current(+)"

Output over current (+)

08XX

"Output over current(-)"

Output over current (-)

09XX

"Input over current(+)"

Input over current (+)

10XX

"Input over current(-)"

Input over current (-)

11XX

"The internal temperature is too high"

The internal temperature is too high

12XX

"The internal temperature is too low"

The internal temperature is too low

13XX

"Connection check error"

Connection check error

14XX

"CH1 & CH2 common-negative connection

prohibited"

Common-negative

connected

to

CH1&CH2 is prohibited

15XX

"Battery polarity reversed!"

Battery has been connected with

polarity reversed.

16XX

"Internal control error"

Internal control checking error

17XX

"Exceed safe time limit"

Safe time limit is exceeded

18XX

"Exceed safe capacity limit"

Safe capacity limit is exceeded

19XX

"Exceed safe temperature range"

Safe temperature range is exceeded

20XX

"Output connection broken"

Output connection is broken

21XX

"Balance port connection error"

Balance port has a connection error

22XX

"Low cell voltage detected on balance port"

Low cell voltage is detected on

balance port

23XX

"High cell voltage detected on balance port"

High cell voltage is detected on

balance port

24XX

"Voltage match error. Balance port sum is lower

than output."

Voltage matched error, the voltage of

the balance port sum is lower than

the output one

25XX

"Voltage match error. Balance port sum is higher

than output."

Voltage matched error, the voltage of

balance port sum is higher than the

output one

26XX

"Number of cells doesn't match the setting"

Number of cells connected doesn't

match the setting

27XX

"Number of cells setting appears low"

Number of cells setting appears low

28XX

"Number of cells setting appears high"

Number of cells setting appears high

29XX

"Balance not needed, Remove connection from

balance port"

Balance port error, Ni-, Pb does not

need balance port, but voltage of

balance port is detected