Program add & manage - run program for charger, Program add & manage, Run program for charger – ProgressiveRC 308Duo iCharger User Manual
Page 13
308DUO V1.6.0
Synchronous Balance Charger/Discharger
- 13 -
Program Add & Manage
Click STOP/START-x button on the initial interface to pop up the BATTERY MEMORY SELECT window.
308DUO has 7 built-in programs
before it enters to the market (shown in the following picture), which cannot be deleted
and are limited for editing. The built-in programs are underline to distinguish them from the customized programs set by
the user.
Click "
" (or long press KNOB)
to pop up the MANAGE
after exiting focus via pressing TAB/SYS, and click
"
" to enter MEMORY SETUP to edit the program, or click "
" to add new program and
enter its editing interface at the same time.
Note: If the program selected is a built-in program, "Copy From…" and "Delete" options are shown in
grey as inactive status, and unable to be set.
Run Program for Charger
After selecting program on BATTERY MEMORY SELECTION, click to enter Run Program interface (long press
STOP/START-x button on the initial interface will enter Run Program from the last running program), as below:
Note: 1. The revised common parameters of built-in program will be saved by default automatically
after running, while the program customized by the user can be set to be saved or not in
MEMORY SETUP→MEMORY OPTION→Auto save before the program runs.
2. After setting the Cap. value, when the Current value exceeds the certain value, the system will
be a warning display and alarm voice(shown in the following picture). The Current value of
each battery type is: LiXX battery :> 3C, NiMH/NiCd battery :> 2C, Pb battery :> 0.3C, NiZn
battery>2C.
1: Run Program Selection
2: Common Parameters Setup
3. Auto- save Hint
1