beautypg.com

Lipo/liio/life battery charge/discharge setup, Lipo/liio/life battery charge setup – ProgressiveRC 308Duo iCharger User Manual

Page 16

background image

308DUO V1.6.0

Synchronous Balance Charger/Discharger

- 16 -

Note: 1. Channel Mode has asynchronous, synchronous available, see more details on

Page10

Dual-channel Connection Notes

.

2. If select synchronous mode, the maximum charge/discharge current setting will change from

30A to 50A.

3. If tick Auto saves before the program runs, the parameters set on the Run program will be

saved automatically, and the Run Program will display “Auto save” ( shown in the following
left picture), otherwise it will display “Don’t save!” (shown in the following right picture); for
the built-in program, the Auto save before the program runs option is ticked by default.

4. If tick Log save to SD card, the log files will be saved to SD card when running program, and

vice versa.

LiPo/LiIo/LiFe Battery Charge/Discharge Setup

After adding a program, it will switch to LiPo/LiIo/LiFe battery in Type option on the MEMORY SETUP interface, and

set the number of cells and capacity, if there is no setting for the number of cells, the charger will set Auto by default.

After editing all parameters for the program, click "

" to save and return to the previous interface.

As shown in the above picture, the program of LiPo, LiIo, LiFe battery has: Charge, Storage, Discharge, Cycle and

Balance Only.

LiPo/LiIo/LiFe Battery Charge Setup

Select Program→Charge to enter Charge setup interface.

Channel Mode:

Asynchronous (default);

Synchronous

Run Counter:

0-999; default: 0

Log Interval:

0.5-60Sec; default: 1Sec

Chg Current:

0.05A-30A; default: 2A

Chg Mode:

Slow Balance, Normal Balance( default),

Fast Balance, User Balance, Not Balance

Chg End Current:

1%-50%; default: 10%

Chg Cell Volt:

3.85V/Cell-4.35V/Cell;

Default: 4.2V/Cell

Cells: Auto(default), 1-8S