beautypg.com

06_cw-250 – Oldcastle BuildingEnvelope Solar Shelf User Manual

Page 6

background image

6






S U N C O N T R O L - I N S T A L L A T I O N M A N U A L

SOLAR ECLIPSE

CW-250 SEALANT

Install CW-2058 cover plate over

anchor once glass is installed.

Attach with (2) FS-322 fasteners.

Seal gap between anchor

and cover plate.

Note:

Typical pressure plates will be installed above

and below cover plate.

See FIGURE 2, page 4 for face cap fabrication.

1/8" GAP

Seal gap between cover plate

and pressure plate typical.

FIGURE 4

1.3 Sealant

6) Clean all surfaces to be sealed using isopropyl alcohol. Then seal cover plate to anchor to

prevent any water infiltration. See FIGURE 4.

7) Pressure plates should be located above and below the cover plate allowing 1/8" joint. This

joint should be cleaned and sealed. See FIGURE 4.