S U N C O N T R O L - I N S T A L L A T I O N M A N U A L

SOLAR SHELF

1 1/16"

1 3/16"

2"

1 1/16"

Drill #11 (.191 dia.) holes &

countersink for #10 pfh

(2) on top and (1) on each side

FIGURE 19

1 1/2"

4.6) Drill (4) #11 (.191 dia.) holes and counter sink for #10 pfh in end of struts. See FIGURE 19. Install

the SS-116 shelf strut onto the shear blocks and attach with (4) four FS-58 fasteners, two on top and

one on either side. See FIGURE 20. Strut to be cut shelf depth minus 2 3/8" for SS-124 & SS125, and

minus 5 1/8" for SS-119 & SS-123.

SS-116

Shelf strut

Locate at mull centerline

and maximum 5'-0" o.c.

Attach w/ (4) FS-58

(#10 X 1" pfh). (2) on top

and (1) on each side