15_shelf – Oldcastle BuildingEnvelope Solar Shelf User Manual
Page 15
15
S U N C O N T R O L - I N S T A L L A T I O N M A N U A L
SOLAR SHELF
™
1 1/8"
9/16"
Cen
ter
line
of
she
lf st
rut
#11 (.191Ø) Holes
Locate on "V"
grooves
1 7/8"
Locate on "V"
grooves
15/16"
#11 (.191Ø) HOLES
FIGURE 14
FIGURE 15
SS-114
SS-118
4.3) Fabricate the SS-114 wall mount (see FIGURE 14) and SS-118 cover retainer (see FIGURE 15)
as shown. Locate holes at center line of shelf struts. (Struts should be located at center line of
vertical mullions. If bay is larger than 5 feet, add an additional strut at mid-lite. Addition struts may
also be required at end cap locations.)
(4) FS-58 (#10 X 1" PFH)
SS-117-01
FIGURE 16
SS-114
Optional Strut Installation
Strut may be installed directly
to wall mount using (4) FS-58
fasteners. Use hole pattern
shown in FIGURE 15.
FIGURE 17
SS-114
4.4) Attach the SS-117-01 shear block to the SS-114 wall mount using (4) four FS-58 (#10 x 1" pfh)
fasteners. See FIGURE 16. Optional assembly: Attach SS-116 strut to SS-114 wall mount with (4)
FS-58 fasteners. See FIGURE 17.
Cen
ter
line
of
she
lf st
rut