12. Technical Data

KISS 4U Short V2 – User's Guide (Version 1.01)

12.2. Mechanical Specifications

Dimensions

KISS 4U Short V2

Height

4U (177 mm) (6.968 ”)

Width

Front: 19” (482 mm); Chassis: 430 mm (16.9")

Depth

Chassis: 301 mm (11.85“)

Weight (without Packaging)

Approx. 13 kg (28.66 lbs.)

Chassis

Chassis, black (RAL 7021)

Front access panel, blue (RAL 5017)

12.3. Environmental Specifications

Thermal Management

2x System fan, temperature controlled (fan slide-in module)
1x CPU fan
1x PSU fan

Operating Temperature

0 … +50 °C (+55 °C at 10% POH per month)

32 ... 122 °F (131 °F at 10% POH per month)

Storage / Transit
Temperature

-20 … +70 °C
(-4 … 158 °F)

Relative Humidity
(Operation/Storage/Transit)

10-95 %, @ 40 °C non condensing

Max. Operation Altitude

2,000 m (6562 ft)

Max. Storage/Transit Altitude

10,000 m (32810 ft)

Operating Shock

15 G, 11 ms, half sine

Storage/Transit Shock

30 G., 11 ms, half sine

Operating Vibration

10 – 500 Hz, 1.0 G

Storage/Transit Vibration

10 – 500 Hz, 2.0 G

Acoustic Noise

< 35 dB(A) at 1 m in front of the system

Protection Class

Front: IP20; optional IP52

www.kontron.com

43