9. Starting Up
KISS 4U Short V2 – User's Guide (Version 1.01)
9.2. DC Power Connection
The DC version of the KISS 4U Short V2 platform is equipped with a +24V or-48V power supply (with a 2-pin terminal block
and an ON/OFF power switch)
It must be ensured that the platform can be powered ON and OFF via an easy accessible two pole isolating
switch and an overload protection. These should be incorporated in the building installation wiring.
The unit is only completely disconnected from the DC power source, when:
it is switched OFF via the ON/OFF switch of the DC PSU
or
the DC power cord is disconnected either from the power source or the unit. Therefore, the DC power
cord and its connectors must always remain easily accessible.
Please ensure that during the DC connection procedure, there is no power flowing from the external
DC power source to the KISS 4U Short V2 system.
9.2.1. Attaching the Ferrite Core
Before you connect the KISS 4U Short V2 with DC Power Supply Unit (PSU) to a DC power source, you have
to attach the ferrite core (7427113, manufacturer: Würth Elektronik) to the wires that are used for the
power connection:
2x 2x wires with a minimum cross section of 2.5 mm
2
for the +24VDC PSU
2x wires with a minimum cross section of 1.5 mm
2
for the -48VDC PSU
Only with the attached ferrite core are ensured the requirements of EMC standards (for emission and
immunity).
Do not close the ferrite core before you have attached it to the power wires!
To attach the ferrite core, proceed as follows:
1. Open the ferrite core as much as possible.
2. Put the two wires together.
3. Lay the wires into the middle channel of the one half of the ferrite core, at 5-8 cm (2-3 in) to one end of the wires. Run
the wires lengthwise, one time around the ferrite core (see figure below), so that the wires are running out at the
other end of the ferrite core.
4. Fold the two halves of the ferrite core, without closing the ferrite case completely.
5. Check the location of the wires in the channel of the ferrite core. If the winding loop is too large, you have to reduce
it, by pulling the end of the longer wires.
6. Close the ferrite core completely until the clamp snaps in place.
5-8 cm [2-3 in] to
power terminals of the
KISS 4U Short V2
Wires to
DC power source
Opened
ferrite core
Fig. 31: Opened ferite core with wires
32