Kontron AM4204 User Manual
Page 50
35
www.kontron.com
12
B1:Temp Air Out
01h
(Temperature)
01h
(Threshold Based)
Temperature Sensor
of the outlet region
Sensor is only readable when
Payload Power is on
13
B1:Temp CPU
01h
(Temperature)
01h
(Threshold Based)
Temperature Sensor
of the CPU
Sensor is only readable when
Payload Power is on
14
B1:Temp Dual GE
01h
(Temperature)
01h
(Threshold Based)
Temperature Sensor
of the dual GE
device (i82571EB
Ethernet
Controller)
Sensor is only readable when
Payload Power is on.
15
B1:Vcc 1.0V
02h
(Voltage)
01h
(Threshold Based)
Voltage on 1.0v
board power supply
Sensor is only readable when
Payload Power is on.
16
B1:Vcc 1.0V BCM
02h
(Voltage)
01h
(Threshold Based)
Voltage on 1.0v
board power supply
Sensor is only readable when
Payload Power is on.
(only valid for AM4220)
17
B1:Vcc 1.1V
02h
(Voltage)
01h
(Threshold Based)
Voltage on 1.1v
board power supply
Sensor is only readable when
Payload Power is on.
18
B1:Vcc 1.2V
02h
(Voltage)
01h
(Threshold Based)
Voltage on 1.2v
board power supply
Sensor is only readable when
Payload Power is on.
19
B1:Vcc 1.8V
02h
(Voltage)
01h
(Threshold Based)
Voltage on 1.8v
board power supply
Sensor is only readable when
Payload Power is on.
20
B1:Vcc 3.3V
02h
(Voltage)
01h
(Threshold Based)
Voltage on 3.3v
board power supply
Sensor is only readable when
Payload Power is on.
21
B1:Vcc 3.3V SUS
02h
(Voltage)
01h
(Threshold Based)
Voltage on 3.3v
suspend
(management)
power supply
Sensor is only readable when
Payload Power is on.
(only valid for AM4204)
23
B1:Vcc 12V
02h
(Voltage)
01h
(Threshold Based)
Voltage on 12v
board power supply
Sensor is only readable when
Payload Power is on.
24
B1:Health Error
24h
(Platform Alert)
03h
(Generic Discrete)
The sensor is an
aggregation of
analog sensors and
shows the healthy
state of the
module. If the
sensor is asserted,
the health LED lit
on amber
Offset 0: no critical sensors
asserted
Offset 1: one or multiple
critical sensors are asserted
See table: Health Sensor list
for details.
25
B1:Pres SFP-1
25h
(Entity Present)
6Fh
(Sensor specific)
The sensor shows
presents or absents
of SFP. No event is
generated.
Offset 0: Entity Present
Offset 1: Entity Absent
Offset 2: Entity Disabled
Sensor is only readable when
Payload Power is on.
(available for AM42xx)
26
B1:Pres SFP-2
25h
(Entity Present)
6Fh
(Sensor specific)
The sensor shows
presents or absents
of SFP. No event is
generated.
Offset 0: Entity Present
Offset 1: Entity Absent
Offset 2: Entity Disabled
Sensor is only readable when
Payload Power is on.
(only available for AM4204
and AM4220)
SDR
ID
Name
Sensor Type Code
Reading Type Code
Description
Event Offset