Kontron AM4210 User Manual
Page 59
44
www.kontron.com
Example: Using onboard
# ipmitool raw 0x3e 0x20
Example: Using ipmitool on Kontron AMC carrier (e.g. AT8404):
# ipmitool –t 0x80 –b 7 raw 0x3e 0x20
Example: Using Kontron carrier manager (AM4904/AM4910):
# clicm Kontron boot set
Example: Using PigeonPoint ShMC:
# clia sendamc 9a 80 0x3e 0x20
Byte Num
Data Field
Request Data
1
Control ID
0 – Boot Image Selection
1 – Interface Settings
2 – PCIe Settings
3 – Image Swap Reset Threshold
2
Control State
Control Number 0: Boot Image Selection
0 – Image0
1 – Image1
Control Number 1: Interface Settings
0 – AM4204 front x4 GE, p8..11 x4 GE
1 – AM4204 front x4 GE, p8..11 x1 XAUI
2 – AM4220 front x2 XAUI
3 – AM4220 front x2 1GE
4 – AM4210 front x1 XAUI, p8..11 x4 GE
5 – AM4210 front x1 XAUI, p8..11 x1 XAUI
6 – AM4210 front x1 GE, p8..11 x4 GE
7 – AM4210 front x1 GE, p8..11 x1 XAUI
Control Number 2: PCIe Settings
0 – PCIe disabled (default)
1 – PCIe Host Mode
2 – PCIe Target Mode (Boot from Bootbus/onboard Flash)
3 – PCIe Target Mode (Boot from PCIe)
Control Number 3: Image Swap Reset Threshold
N – count of detected resets before image swap
0,1 = invalid values (will be rejected)
255 = disable logic
Control Number 4:
0 – local PCIe clock enabled
1 – FCLKA support enabled
Response Data
1
Completion Code