Configuration – Kontron VM62 User Manual
Page 39
VM62(A) / VM42(A) User’s Manual
Chapter 3 Configuration
3
3. C
ONFIGURATION
The VM62(A) / VM42(A) has twelve jumpers fitted to the board. The list of default jumper settings is shown below.
Table 3.0.0.1: VM62(A) / VM42(A) Default Jumper Settings
Jumper
Default Setting
Description
Wire
J1
Set
SYSCLK connected to VME
J2
Set
On-board RESET generator to VME
J8
Open
Boot from VME disabled
J9
Open
Boot from MP memory interface disabled
Solder
J3
J4
J5
Dependent on board
CPU frequency
J6
Set
Clock connected to 68EN360
J7
Dependent on board
CPU type
J10
Open
Write protection of EEPROM disabled
J11
J12
Dependent on board
SRAM size
J14
Open
Signal GND not connected to Protective GND
J131 - J134
Dependent on board
Processor power supply
Note
Jumpers J1, J2, J8 and J9 are normal wire jumpers that can be configured by the user. The other
jumpers are solder jumpers and are factory set.
May 17, 1996
© 1995 PEP Modular Computers
Page 3-1