beautypg.com

7 software support, 7 software support - 12, Introduction cp384 – Kontron CP384 User Manual

Page 28

background image

Kontron Modular Computers GmbH

ID 31440, Rev. 01

P R E L I M I N A R Y

Re

vNr. = CP384

-

31440

_01 -

06

0503

/14

4228

Page 1 - 12

Introduction

CP384

1.7

Software Support

The CP384 is supplied with appropriate driver software which provides software interfacing to
the System Master. The CP384 supports Windows XP

, Windows NT 4.0

, Windows 2000

,

VxWorks

and Linux

.

External Supply Voltage (VCC)

+ 24V ± 20% (working range)

External Supply Current (VCC)

All relays ON:

• 90 mA at 19.2V
• 110 mA at 24

.0

V

• 130 mA at 28.8V

Signal Output
Over Current Protection

No over current protection is provided by the CP384 for the digital outputs. If
over current protection is required, it must be provided by the application sys-
tem.

External Power Supply

For proper operation of the output channels the external power supply voltage
(EXTVCC) must be within the range: + 19.2 V to 28.8 V DC.
If the EXTVCC is below or above the specified range, proper operation of the
output channels is not guaranteed.
For invalid values of EXTVCC, the output cluster is forced into the reset state
resulting in all relays being switched off and the outputs switched to the NC
position.

Output RC units

There are capacitor filters connected to the output channel pins: COM, NO,
NC.

Isolation

2 kV process to system

Table 1-5: CP384 Digital Output Specifications (Continued)

TYPE