Introduction
CP384
1.7
Software Support
The CP384 is supplied with appropriate driver software which provides software interfacing to
the System Master. The CP384 supports Windows XP
, Windows NT 4.0
, Windows 2000
,
VxWorks
and Linux
.
External Supply Voltage (VCC)
+ 24V ± 20% (working range)
External Supply Current (VCC)
All relays ON:
• 90 mA at 19.2V
• 110 mA at 24
.0
V
• 130 mA at 28.8V
Signal Output
Over Current Protection
No over current protection is provided by the CP384 for the digital outputs. If
over current protection is required, it must be provided by the application sys-
tem.
External Power Supply
For proper operation of the output channels the external power supply voltage
(EXTVCC) must be within the range: + 19.2 V to 28.8 V DC.
If the EXTVCC is below or above the specified range, proper operation of the
output channels is not guaranteed.
For invalid values of EXTVCC, the output cluster is forced into the reset state
resulting in all relays being switched off and the outputs switched to the NC
position.
Output RC units
There are capacitor filters connected to the output channel pins: COM, NO,
NC.
Isolation
2 kV process to system
Table 1-5: CP384 Digital Output Specifications (Continued)
TYPE
DESCRIPTION