Testing the outflow allows you to determine the efficiency of the left pump head.
1

Remove the left outflow hose from the left outflow catch bottle.

2

Attach the left outflow hose to the bottom port of the flow meter.

3

Turn the air pump on.

4

Record the flow meter reading in a data table on page 16.
If the flow meter reading is below the testing range, rebuild the pump head.
Pump head rebuild kits (P/N 79190003) are available from Dynojet.
Note: Dynojet recommends rebuilding both pump heads at the same time.

5

Turn the air pump off.

6

Replace the left outflow hose into the left outflow catch bottle.