129
voice.
5. In (4) Sensor, select and click on the sensor number (use and to select the sensor) to set the
condition for the system to alarm. If the sensor normal status is high, set the sensor condition to low.
- Continue trigger duration: Set a time period that when sensor has been trigger and stay in the
same status for that period, then the alarm will be sent out.
- Abnormal Event: Enable/disable to set the condition of the event for system to alarm..
System Reboot: when the DVR system reboot without abnormal condition, the system will send
out the alarm message.
Abnormal Reboot: when the DVR system reboot in irregular condition, the system will send out
the alarm message.
Recording is switched off: when the recording has been stopped, the system will send out the
alarm message.
Network is switched off: when the network connection of DVR system is lost, the system will
send out the alarm message.
Hard Disk failed:
when the hard disk can’t work normally, the system will send out the alarm
message.
- POS Keyword: Enable/disable to scan the data from the POS if it matches the keyword.
- Alarm Message: To active with external alarm message by your own program. For the detail
configuration, please contact the local reseller.
- Alarm Button: Enable/disable to active manual alarm function (see also Chapter 2.2#(19)). To define
alarm message of manually alarm trigger. Click alarm button and select the alarm button # and fill in
the description of alarm button.