SPECIFICATIONS

Flash Type:

Useable Exposure

Modes:

Guide Numbers:

Angle of Coverage:

Batteries:

Number of Flashes/

Recycling Time:

Useable Ranges:

Resistant Pressure:

Target-Light:

Slave Flash Function:

Dimensions:

Weight:

Note:

All performance data

[25°C(77°F)1

High-performance silicon­

controlled rectifier and series

circuitry

TTL auto exposure (with Nikonos-V

camera); Non-TTL auto exposure

(with optional Sensor Unit
SU-101); and Manual: “MFULL,”

“M1/4," and "M1/16” settings

With ASA/ISO 100 film on land
(underwater), full output: 32 (16):

1/4 output: 16(8); 1/16 output:

8(4)
79° on land; covers picture angle

of 28 mm lens on land and under­
water; with Wide-Flash Adapter

SW-102, picture angle increases

to that of a 15mm lens
Six C-type NiCd batteries or six

C-type alkaline-manganese

batteries (high-performance

manganese batteries not

recommended)
NiCd*: 70 flashes/minimum

approx. 5sec.** (depending upon

battery brand and amount of

recharging)

Alkaline-manganese: 120 flashes/
minimum approx. 14sec.**

* Data for C-type NiCd batteries

are applicable only when bat­
teries with a 1200mAh capacity
have been recharged by a 120 mA
current for 15 hours at room
temperature.

** More flashes and shorter

recycling times in the TTL,

non-TTL, "M1/4,” and "M1/16”
modes

TTL: ASA/ISO film speed coupling

range: ASA/ISO 25 to 400: useable

aperture range: f/2.8 to f/22 (at
ASA/ISO 100); coupling distance

range: 0.3m (1ft) to 11m (36.1ft)

(at ASA/ISO 100 on land): 0.3m
(1ft) to 5.6m (18.4ft) (at ASA/ISO

100 underwater)
Non-TTL: Useable apertures: f/4

and f/8 (at ASA/ISO 100); coupling
distance range: 0.6m (2ft) to 8m
(26.2ft) (at ASA/ISO 100 and f/4
on land); 0.6m (2ft) to 4m (13.1 ft)
(at ASA/ISO 100 and f/4 under­

water): 0.6m (2ft) to 4m (13.1 ft)
(at ASA/ISO 100 and f/8 on land);
0.6m (2ft) to 2m (6.6ft) (at

ASA/ISO 100 and f/8 underwater)

6kg/cm2 (85 Ib/in^) maximum:
useable to depths of 50m (I60ft)

Indicates direction of flash head

when T-S switch is at “T.LIGHT"

or "T&S"
Wireless: triggered by light from
another flash unit when T-S switch

is at "SLAVE” or "T&S"
Flash head: Approx. 139mm(W)x
152.5mm(H)x212mm(D)
Flash head without batteries:

Approx. 1670g

are for normal-temperature operation

Supplied with ten items:

Main flash head (including battery

cartridge), joint, bracket (with separate bracket screw), cord fastening

hanger. Wide Flash Adapter SW-102, 0-ring set. target light, sync cord,

arm, and speedlight case SS-101.