ADJUSTMENTS

■ If the tooth was too close to the square, back the

bracket away with the block of wood and hammer.

■ Tighten the screws, raise the blade and recheck.

■ Repeat until blade is parallel to miter gage groove.

■ If the blade is not parallel, adjust the front table

bracket. Tilt the blade to 45' with the blade lock

handle and bevel handwheel.

■ From the back of the saw. loosen the bolts holding

the front table bracket, as welt as the rear table
bracket.

■ Reposition the blade to 90' with the bevel hand­

wheel and blade lock handle.

■ Lower the blade and move the brackets as needed.

Retighten all bracket screws.

■ Raise the blade and recheck. Repeat until the

blade is parallel to the miter gage groove.

■ Place the throat plate in the opening and push it

toward the rear of saw base to engage the spring
clip.

Note: The keyslot in the throat plate will drop over the

front screw.

■ Tighten the screw. Do not allow the throat plate to

bow up above the table surface.

SAW TABLE VIEW FROM BELOW

TABLEBMCKET

REAR

BRACKET

SCREW(S)

FRONT

TABLE BRACKET

FRONT-

BRACKET

SCREWfS)

Fig. 37

SETTING THE BEVEL STOPS AND INDICATOR

See Figures 38 and 39.

WARNING;

Make sure the switch is off, the

switch key is removed, and your saw is
unplugged. Failure to do so could result in
accidental starting, resulting in serious personal
injury.

The bevel scale should show O' when the blade is set

vertical at 90' to table, and 45* when blade is at 45* tilt.

■ Raise the blade all the way up by turning the height

handwheel. Lift the blade guard.

■ Loosen bevel lock handle and turn the bevel

handwheel clockwise to tilt the blade. Reverse it

and turn the handwheel counterclockwise until it

stops.

■ Check the blade angle with a combination square.

Don’t let the square touch a blade tooth. The blade
should be at 90' and the scale indicator at 0*.

Note; The scale indicator is the pleistic plate on the

scale at the front of the cabinet.

■ If the scale indicator does not point to O', loosen the

scale indicator with a screwdriver, adjust it within

the slot, and retighten the screw,

■ If the blade angle Is wrong, adjust the 90’ stop

screw (left of the blade, looking from the front). Start
by turning the 90' stop screw three or four turns

with a 4 mm hex key.

90® STOP SCREW

45® STOP SCREW

4 mm

HEX KEY

Fig. 38

Turn the bevel handwheel clockwise once, then

back counterclockwise to square blade with table.

Tighten the 90' stop screw and recheck that the
blade is square in a 90* position. If not, repeat.

When the blade is square, check the scale indica­

tor. If it is not at zero, reset the scale indicator as

before.

CRflFTSMRN* TABLE SAW 315.228310

30