beautypg.com

Rgure 6 – Craftsman 139.53675SRT User Manual

Page 23

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

» Center each sensor unit in a 'C* wrap with tenses

pointing toward each other across the door (see
Hgure 6).

• Secure sensors with the hardware shown. Roger

tighten the wing nut on the

receiving eye

to aliow

for final adjustment. Securely tighten the

sending

eye

wing nut

• Run the wires from both sensors to the opener.

Use insulated staples to secure wire to waJ! and
ceiling,

«Strip 1/4“ of insulation from each set of wires.

Separate white and whiie/black wires sufficiently to
connect to the opener terminal screws: white to 2
and white/black to 3.

Aligning the Safety Sensors

• Plug in the opener. Green indicator lights in both

the sending and receiving eyes will

glow steadily il

wiring connections and alignment are correct

The

sending

eye indicator light will giow regardless

of alignment or obstruction. If the indicator light is
off, dim, or flickering in the

receiving eye

(and the

invisible light beam path is not obstructed),
alignment is required.

• Loosen the

sending eye

wing nut and readjust,

aiming directly at the receiving eye. Lock in place.

• Loosen the

receiving

eye wing nut and adjust

sensor vertically and/or horizontally untii it receives
the sender^s beam. When the green indicator light

glows steadily,

tighten the wing nut.

Hardware Shown Actual Size

l/4-20xM/a*

_

He* Soft

Rgure 6

'C'Wrap

¡mficator

Ugh!

1/4-23x1-1/2*

Hex Boil

Trouble Shooting

1. if the

sending eye

indicator light does not

glow

steadily

after installation, check for

• Bectric power to the opener.

• A short in the white or white/black wires. These

can occur under staples or at screw terminal
connections.

• Incorrect wiring between sensors and opener,

• An open wire (wire break).

2. if the sending eye indicator light

glows steadily

but

the receiving eye indicator light doesn*t

■ Check alignment.

• Check for an open wire to the receiving eye,

3. If the receiving eye indicator light is dim, realign

either sensor.

NOTE:

When the invisible beam path is obstructed or

misaligned while the door is closing, the door wilt
reverse. If the door is already open, it will not dose.

The opener fights will flash 10 times. (Ifbutbs are not

instalied, 10 dicks are audible.) See page 21.

Sonspr

InvistbS« Light Beam

Protection Afea

Sensor

23