beautypg.com

Warning, Heater selection chart, Caution – Qmark HRK - Single Element Infrared Heaters User Manual

Page 2: Optional mechanical accessories

background image

LIMITED WARRANTY

All products manufactured by Marley Engineered Products are warranted
against defects in workmanship and materials for one year from date of instal-
lation, except heating elements which are warranted against defects in work-
manship and materials for two years from date of installation. This warranty
does not apply to damage from accident, misuse, or alteration; nor where the
connected voltage is more than 5% above the nameplate voltage; nor to equip-
ment improperly installed or wired or maintained in violation of the product’s
installation instructions. All claims for warranty work must be accompanied by
proof of the date of installation.

The customer shall be responsible for all costs incurred in the removal or rein-
stallation of products, including labor costs, and shipping costs incurred to
return products to Marley Engineered Products Service Center.Within the limi-
tations of this warranty, inoperative units should be returned to the nearest
Marley authorized service center or the Marley Engineered Products Service
Center, and we will repair or replace, at our option, at no charge to you with
return freight paid by Marley. It is agreed that such repair or replacement is the
exclusive remedy available from Marley Engineered Products.

THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES
EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH
EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DIS-
CLAIMED

AND

EXCLUDED

FROM

THIS

AGREEMENT.

MARLEY

ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL
DAMAGES ARISING WITH RESPECT TO THE PRODUCT, WHETHER
BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT.

Some states do not allow the exclusion or limitation of incidental or conse-
quential damages, so the above exclusion or limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights which vary from state to state.

For the address of your nearest authorized service center, contact Marley
Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise
returned to the factory must be accompanied by a return authorization and ser-
vice identification tag, both available from Marley Engineered Products. When
requesting return authorization, include all catalog numbers shown on the prod-
ucts.

INSTALLATION OF ELEMENTS

1. Place heater on flat surface and remove both wiring compartment covers.

2. Remove the outside hex nut from both ends of the element.

3. Place the element in the “L” shaped slots in the heater housing.

4. Install ring terminal on factory installed wire assemblies on the threaded studs on

both sides of element. See Fig. 1.

5. Replace hex nut and secure

6. Replace wiring compartment covers.

APPLICATION LIMITATION AND PRECAUTIONS

Hazardous Atmosphere - These heaters are not suitable for use in hazardous

locations.

Indoor Use Only

Ceiling Mount Only - Do not mount to walls.

Maintain at least 5’ (1.5 m) in radiant path between bottom of heater and com-

bustible material.

Corrosive Atmospheres - The high quality finish and steel internal sheet metal

parts will give excellent service under most operation conditions, including coastal

salt air and most industrial atmospheres. However, the finish is not intended for

salt spray exposure in marine applications or highly corrosive greenhouse, swim-

ming pool, chemical storage or industrial atmospheres.

The mounting structure and anchoring hardware must be capable of reliably

supporting the total weight of the heater and all accessories.

INSTALLATION OF HEATER

1. Cut suspension chain (approved) to desired mounting length.

2. Attach chain to heater with “S” hooks provided. Heater must be mounted so that

element is horizontal

3. Tilt heater (if desired) by adjusting chains as shown in Fig 2.

WIRING

1. Supply wiring coming to heater must be rated at least 90 degrees C. USE COP-

PER WIRING ONLY.

2. Rough-in Wiring. Run supply wiring to the heater location (Check heater nameplate

and element for proper supply voltage.) Check the amperage of the heater (refer

to nameplate on heater) and verify the supply wiring is properly fused.

3. Wire heaters as shown in Fig. 3.

Fig. 1

Fig. 2

WARNING

SUPPLY WIRING MUST BE SIZED FOR MAXIMUM WATTAGE
OF HEATER WITH QUARTZ TUBE.

!

Line Voltage

Thermostat

or switch

(not included

- see catalog)

Fig. 3

HEATER SELECTION CHART

DO NOT HANDLE QUARTZ LAMP OR QUARTZ TUBE HEATING ELEMENTS
WITH BARE HANDS AS SALT IN PERSPIRATION MAY DETERIORATE THE
QUARTZ.

CAUTION

!

Dimensions

Model No.

Volts Watts

Reflective

Height

Width

Length

Wt.

Angle

in. (mm)

in. (mm) in. (mm) lb (kg.)

RK41512

120

1500

RK42020

208

2000

RK42024

240

2000

RK42027

277

2000

46 (1168)

9 (4.1)

RK42034

347

2000

RK42048

480

2000

RK42060

600

2000

60 (Sym)

3.375 (86)

5.5(140)

RK53020

208

RK53024

240

RK53027

277

3000

RK53034

347

57 (1448)

11 (5.0)

RK53048

480

RK53060

600

Part No. 5200-2395-002

ECR 37239

5/07

470 Beauty Spot Rd. East
Bennettsville, SC 29512 USA

2

OPTIONAL MECHANICAL ACCESSORIES

Quartz Tube

Ring Terminal

Hex Nut

Model No.

Description

Carton

Wt.

Qty.

lbs (gr.)

WG46

Wire Guard

1

1 (454)

WG57

1.5 (680)

RP-WMB

Wall Mounting Bracket

1

2 (907)

HOW TO OBTAIN WARRANTY SERVICE AND
WARRANTY PARTS PLUS GENERAL INFORMATION

1. Warranty Service or Parts

1-800-642-4328

2. Purchase Replacement Parts

1-800-654-3545

3. General Product Information

www.marleymep.com

Note: When obtaining service always have the following:

1. Model number of the product
2. Date of manufacture
3. Part number or description