beautypg.com

Operating instructions – Qmark GFR Series - Fan-Forced Wall Heaters User Manual

Page 4

background image

TO INSTALL FAN DECK ASSEMBLY

NOTE: Fan deck assembly should not be installed until after the
drywall phase of construction is complete. Dust from drywall
installation and joint compound can be harmful if it gets inside
fan deck components.

1. Locate fan deck and mounting rails in top of back box.
2. Insert flanges on fan deck into mounting rails and slide back

until fan deck stops (see Figure 6).

3. Make wiring connections, attaching one red and one black

thermostat lead to two (2) black heater leads for 240V or to
black and white heater leads for 120V with wirenuts (provid-
ed). Connect field ground lead to bare ground wire with
wirenut (provided). See Figure 7.

4. Remove 1/2” knockout from grille and install grille using two

oval head screws. Push thermostat knob on thermostat shaft.

5. Reconnect power at main fuse or circuit breaker distribution

panel.

TO CHANGE WATTAGE OUTPUT

The chart shows the wattages available by model. Each heater is
factory wired for its maximum wattage. The last two columns in
the chart refer to the jumpers on the CLIP ‘n’ Fit

®

Board. To change

wattage, clip out Jumper 1 and/or Jumper 2 as shown in the chart
below. Completely remove jumpers by clipping at both ends as
close to the board as possible (See Figure 8).

OPERATING
INSTRUCTIONS

1. Heater must be properly installed before operation.
2. After heater is completely assembled, rotate thermostat knob

counterclockwise until control stops. This is the minimum
heat setting.

3. Turn power supply to heater “ON” at main switch panel.
4. Heater should not operate. If it operates disconnect power

and recheck wiring.

5. Rotate thermostat clockwise until it stops (maximum heat set-

ting).

6. Heater and fan should come on. If heater and fan do not

come on, disconnect power and check wiring.

7. Allow heater to continue to operate until room temperature

reaches desired comfort level. Then rotate thermostat knob
counterclockwise slowly until thermostat clicks off.

4

TOP OF BACK BOX

FLANGE ON FAN DECK

MOUNTING RAIL

Figure 6

TABLE 2

TOTAL AMPS

0 thru 12

12.1 thru 16
16.1 thru 24

WIRE SIZE

(COPPER)

#14
#12
#10

CIRCUIT BREAKER

OR FUSE SIZE

15 Amps
20 Amps
30 Amps

TABLE 1

MODEL

R1500FC

R1500T2FC

R2004FC

R2004T2FC

R2404FC

R2404T2FC

VOLTS

120

240
208
240
208

WATT/AMP

1500/12.5

2000/8.3

1500/7.2

2400/10.0

1800/8.7

WATT/AMP

1125/9.4

1500/6.3

1125/5.4

1800/7.5

1350/6.5

WATT/AMP

750/6.3

1000/4.2

750/3.6

1200/5.0

900/4.3

WATT/AMP

375/3.1

500/2.1

375/1.8

600/2.5
450/2.2

WATTAGE

JUMPER

1

JUMPER

2

2400

1800

1200

600

1800
1350

900
450

2000
1500
1000

500

1500

1125

750
375

1500

1125

750
375

Red

Jumper

Leave in
Leave in

Clip out
Clip out

Blue

Jumper

Leave in

Clip out

Leave in

Clip out

R2404FC &

R2404T2FC

@240V @208V

R2004FC &

R2004T2FC

@240V @208V

R1500FC &

R1500T2FC

@120V

SELF HOLD
LIMIT

TEMPERATURE
REGULATOR

Figure 7 - Wiring Diagram

R Series only

RT2 Series only

Figure 8 Clip’n’Fit

®

Board