Compaq PROLIANT ML350 User Manual
Page 73
Connectors, Switches, and LEDs
4-14
Compaq ProLiant ML350 Generation 3 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL Codename: Steel Dragon Part Number: 278704-002 Last Saved On: 12/18/02 9:49 AM
Table 4-7: Hot-Plug SCSI Hard Drive LED Combinations
Activity Online
Fault
Meaning
On Off
Off
Do not remove the drive. Removing a
drive during this process causes data
loss.
The drive is being accessed and is not
configured as part of an array.
On Flashing
Off
Do not remove the drive. Removing a
drive during this process causes data
loss.
The drive is rebuilding or undergoing
capacity expansion.
Flashing Flashing
Flashing
Do not remove the drive. Removing a
drive during this process causes data
loss.
The drive is part of an array being selected
by the Array Configuration utility (ACU).
-Or-
The Options ROMPaq is upgrading the
drive.
Off
Off
Off
It is OK to replace the drive online if a
predictive failure alert is received (refer to
the “Predictive Failure Alert” section in the
Compaq Servers Troubleshooting Guide for
details) and the drive is connected to an
array controller.
The drive is not configured as part of an
array.
-Or-
If this drive is part of an array, a
powered-up controller is not accessing the
drive.
-Or-
The drive is configured as an online spare.
Off
Off
On
It is OK to replace the drive online.
The drive has failed and has been placed
offline.
continued