beautypg.com

Compaq PROLIANT ML350 User Manual

Page 73

background image

Connectors, Switches, and LEDs

4-14

Compaq ProLiant ML350 Generation 3 Server Maintenance and Service Guide

COMPAQ CONFIDENTIAL Codename: Steel Dragon Part Number: 278704-002 Last Saved On: 12/18/02 9:49 AM

Table 4-7: Hot-Plug SCSI Hard Drive LED Combinations

Activity Online

Fault

Meaning

On Off

Off

Do not remove the drive. Removing a
drive during this process causes data
loss.

The drive is being accessed and is not
configured as part of an array.

On Flashing

Off

Do not remove the drive. Removing a
drive during this process causes data
loss.

The drive is rebuilding or undergoing
capacity expansion.

Flashing Flashing

Flashing

Do not remove the drive. Removing a
drive during this process causes data
loss.

The drive is part of an array being selected
by the Array Configuration utility (ACU).

-Or-

The Options ROMPaq is upgrading the
drive.

Off

Off

Off

It is OK to replace the drive online if a
predictive failure alert is received (refer to
the “Predictive Failure Alert” section in the
Compaq Servers Troubleshooting Guide for
details) and the drive is connected to an
array controller.

The drive is not configured as part of an
array.

-Or-

If this drive is part of an array, a
powered-up controller is not accessing the
drive.

-Or-

The drive is configured as an online spare.

Off

Off

On

It is OK to replace the drive online.

The drive has failed and has been placed
offline.

continued