background image

CY7C1386DV25, CY7C1386FV25

CY7C1387DV25, CY7C1387FV25

Document Number: 38-05548 Rev. *E

Page 14 of 30

TAP AC Test Conditions

Input pulse levels .................................................V

SS

to 2.5V

Input rise and fall time..................................................... 1 ns
Input timing reference levels .........................................1.25V
Output reference levels.................................................1.25V
Test load termination supply voltage.............................1.25V

TAP AC Output Load Equivalent

TAP AC Switching Characteristics

Over the Operating Range

[11, 12]

Parameter

Description

Min.

Max.

Unit

Clock
t

TCYC

TCK Clock Cycle Time

50

ns

t

TF

TCK Clock Frequency

20

MHz

t

TH

TCK Clock HIGH time

20

ns

t

TL

TCK Clock LOW time

20

ns

Output Times
t

TDOV

TCK Clock LOW to TDO Valid

10

ns

t

TDOX

TCK Clock LOW to TDO Invalid

0

ns

Setup Times
t

TMSS

TMS Setup to TCK Clock Rise

5

ns

t

TDIS

TDI Setup to TCK Clock Rise

5

ns

t

CS

Capture Setup to TCK Rise

5

ns

Hold Times
t

TMSH

TMS Hold after TCK Clock Rise

5

ns

t

TDIH

TDI Hold after Clock Rise

5

ns

t

CH

Capture Hold after Clock Rise

5

ns

TDO

1.25V

20pF

Z = 50

O

50

TAP DC Electrical Characteristics And Operating Conditions

(0°C < TA < +70°C; V

DD

= 2.5V ±0.165V unless otherwise noted)

[13]

Parameter

Description

Test Conditions

Min.

Max.

Unit

V

OH1

Output HIGH Voltage

I

OH

= –1.0 mA

1.7

V

V

OH2

Output HIGH Voltage

I

OH

= –100 µA

2.1

V

V

OL1

Output LOW Voltage

I

OL

= 1.0 mA

0.4

V

V

OL2

Output LOW Voltage

I

OL

= 100 µA

0.2

V

V

IH

Input HIGH Voltage

1.7

V

DD

+ 0.3

V

V

IL

Input LOW Voltage

–0.3

0.7

V

I

X

Input Load Current

GND < V

IN

< V

DDQ

–5

5

µA

Note

11. t

CS

and t

CH

refer to the setup and hold time requirements of latching data from the boundary scan register.

12. Test conditions are specified using the load in TAP AC test conditions. t

R

/t

F

= 1ns.

13. All voltages referenced to V

SS

(GND).

[+] Feedback