Dell PowerVault DP500 User Manual
Page 14

14
Introduction
NOTE:
Do not install the iSNS Server software on Initiator (host) or Target
(PowerVault500/PowerVault 600 storage system). Install the software on a
separate Client/Server running Windows operating system.
3 Turn on the PowerVault 500/PowerVault 600 storage system.
4 Create one or more volumes on the local drives for creating Virtual Disks
for iSCSI Targets.
From Initiator Server/Client
1 Configure the Microsoft iSCSI Initiator with iSNS server's information.
Go to Start
→ Programs→ Microsoft iSCSI Initiator→ Discovery tab→
Add.
2 Add the IP address of the iSNS server and click OK.
Verifying the iSNS Server Settings (Optional)
1 In the iSNS Server, go to iSNS Server Properties→ General tab.
The Registered iSCSI Initiators and Targets list is displayed.
2 The iSCSI Initiator that you added is listed.
Setting Up the Target (PowerVault 500/PowerVault 600 Storage System)
1 Go to the PowerVault 500/PowerVault 600 storage system. Select Start→
Programs
→ Administrative Tools→ Microsoft iSCSI Software Target to
open Microsoft iSCSI Software Target console. Select the iSCSI Target,
right-click and select Properties.
2 In the iSCSI Target Properties window, go to the iSNS tab and add the
iSNS server information (DNS Name or IP address).
3 Repeat step 2 to step 5 in the "Creating the Target" on page 9. When you
use the Browse option, the iSCSI Initiator Identifier of all Initiators that
are registered with iSNS server are listed.
NOTE:
The iSCSI Target may cause errors when you query the iSNS server
for Initiator discovery. This is a known issue and will be addressed in a future
release.