Dell PowerVault DP500 User Manual
Page 28
28
Detailed End-to-End iSCSI Setup
a
Choose this option to enable MPIO and select Advanced.
b
Go to Advanced Settings
→ General tab and select the following
options from the drop-down menu:
•
Local Adapter — Microsoft iSCSI Initiator
•
Source IP — one of the host IP addresses
•
Target Portal — iSCSI IP address of the PowerVault NF500/NF600
storage system.
c
In the Advanced Settings window, click OK. In the Log On to Target
window, click OK.
The Targets tab now displays the Target status as Connected.
5 In the Log On to Target screen, you can use the Advanced.. option for
other advanced options like CRC/Checksum and IPSec Settings. For more
information, see "Appendix" on page 35.
6 In the Log On to Target screen, click OK.
The connection is established and the status is displayed as Connected.
7 To configure MPIO, repeat step 1 through step 6 and select the following
options:
a
Selecting the Target that is Connected and click LogOn.
b
In the Logon to Target window, select Advanced.., and then select the
IP address of a different host.
c
In the Advanced Settings window, select the redundant iSCSI
IP address of the PowerVault NF500/NF600 storage system.
Selecting the redundant iSCSI IP address ensures that the iSCSI
network traffic and the public network traffic are on separate subnets.
This also allows load balancing/failover.
NOTE:
You can also configure load balancing and failover by using Microsoft
MPIO support or Multiple Connections per Session (MC/S). Currently the
PowerVault NF500/NF600 storage systems only supports the MPIO option. The
MC/S option is not supported with PowerVault NF500/NF600 storage solution
and PowerVault NF500/NF600 cluster systems.
8 From Disk Management, configure the iSCSI Target device. Go to the
iSCSI Initiator host and click Start
→ Control Panel → Administrative
tools
→ Computer Management→ Disk Management.