Dell Latitude C500 User Manual
Page 129
was booting.
Memory
address line
failure at
address, read
value
expecting
value
An installed memory module may
be faulty or improperly seated.
Reseat the
and, if necessary,
replace them.
Memory
allocation
error
The software you are attempting
to run is conflicting with the
operating system, another
application program, or a utility.
Turn off the computer, wait 30 seconds, and then
restart it. Try to run the program again. If the
problem persists, contact the software company.
Memory data
line failure
at address,
read value
expecting
value
An installed memory module may
be faulty or improperly seated.
Reseat the
and, if necessary,
replace them.
Memory double
word logic
failure at
address, read
value
expecting
value
An installed memory module may
be faulty or improperly seated.
Reseat the
and, if necessary,
replace them.
Memory
odd/even
logic failure
at address,
read value
expecting
value
An installed memory module may
be faulty or improperly seated.
Reseat the
and, if necessary,
replace them.
Memory
write/read
failure at
address, read
value
expecting
value
An installed memory module may
be faulty or improperly seated.
Reseat the
and, if necessary,
replace them.
No boot
device
available
The computer cannot find the
diskette or hard-disk drive.
If the diskette drive is your boot device, make sure
that there is a bootable diskette in the drive. If the
hard-disk drive is your boot device, make sure
that the drive is installed, properly seated, and
partitioned as a boot device.
No boot
sector on
hard-disk
The operating system may be
corrupted.
Reinstall your operating system. See the
documentation that came with your operating
system.