About Your System
29
Timer chip
counter 2 failed.
Faulty system board.
TPM
configuration
operation
honored. System
will now reset.
A Trusted Platform Module
(TPM) configuration
command has been
entered. The system will
reboot and execute the
command.
Information only.
TPM
configuration
operation is
pending. Press
(I) to Ignore OR
(M) to Modify to
allow this change
and reset the
system.
WARNING:
Modifying could
prevent
security.
This message displays
during system restart after
a TPM configuration
command has been
entered. User interaction is
required to proceed.
Enter I or M to proceed.
TPM failure.
A TPM function has failed. See "Getting Help" on
Unable to launch
System Services
image. System
halted!
System halted after F10
keystroke because System
Services image is either
corrupted in the system
firmware or has been lost
due to system board
replacement.
Restart the system and update
the Dell USC repository to the
latest software to restore full
functionality. See the Dell
USC user documentation for
more information.
Unexpected
interrupt in
protected mode.
Improperly seated memory
modules or faulty keyboard
or mouse controller chip.
Reseat the memory modules.
Memory" on page 119. If the
problem persists, see "Getting
Message