Dell PowerEdge T110 II User Manual
Page 28
28
About Your System
The following
DIMMs should
match
in
geometry:
x,x,...
Invalid memory
configuration. The
specified memory modules
do not match in size,
number of ranks, or
number of data lanes.
Ensure that the memory
modules are installed in a valid
configuration. See "General
The following
DIMMs should
match
in rank
count:
x,x,...
The following
DIMMs should
match in size:
x,x,...
The following
DIMMs should
match
in size
and geometry:
x,x,...
The following
DIMMs should
match
in size
and rank count:
x,x,...
Thermal sensor
not detected on
x.
A memory module without
a thermal sensor is installed
in the specified memory
slot.
Replace the memory module.
Time-of-day
clock stopped.
Faulty battery or faulty
chip.
Time-of-day not
set - please run
SETUP program.
Incorrect Time or Date
settings; faulty system
battery.
Check the Time and Date
settings. See "Using the
page 35. If the problem
persists, replace the system
battery. See "System Battery"
Message
Causes
Corrective Actions