Dell PowerEdge 1900 User Manual
Page 20

20
About Your System
E1913
CPU & Firmware
Mismatch
The BMC firmware does not
support the CPU.
Update to the latest BMC
firmware. See the BMC User’s
Guide for more information on
setup and use of BMC.
E2010
No Memory
No memory is installed in the
system.
Install memory. See "Memory" on
page 80.
E2011
Mem Config Err
Memory detected, but is not
configurable. Error detected
during memory configuration.
See "Troubleshooting System
Memory" on page 110.
E2012
Unusable Memory
Memory is configured, but not
usable. Memory subsystem
failure.
See "Troubleshooting System
Memory" on page 110.
E2013
Shadow BIOS Fail
The system BIOS failed to copy
its flash image into memory.
See "Troubleshooting System
Memory" on page 110.
E2014
CMOS Fail
CMOS failure. CMOS RAM not
functioning properly.
See "Getting Help" on page 131.
E2015
DMA Controller
DMA controller failure.
See "Getting Help" on page 131.
E2016
Int Controller
Interrupt controller failure.
See "Getting Help" on page 131.
E2017
Timer Fail
Timer refresh failure.
See "Getting Help" on page 131.
E2018
Prog Timer
Programmable interval timer
error.
See "Getting Help" on page 131.
E2019
Parity Error
Parity error.
See "Getting Help" on page 131.
E201A
SIO Err
SIO failure.
See "Getting Help" on page 131.
E201B
Kybd Controller
Keyboard controller failure.
See "Getting Help" on page 131.
E201C
SMI Init
System management interrupt
(SMI) initialization failure.
See "Getting Help" on page 131.
E201D
Shutdown Test
BIOS shutdown test failure.
See "Getting Help" on page 131.
E201E
POST Mem Test
BIOS POST memory test failure. See "Troubleshooting System
Memory" on page 110. If problem
persists, see "Getting Help" on
page 131.
Table 1-4.
LCD Status Messages (continued)
Code
Text
Causes